HBH / HBH-K

Ref. Std. TS 2814 HFFR, Internal Installation Telephone Cables Application These cabels are used indoor installations, central and subscriber distribution cable and signal communications. The screen protects the cable core against electrical noises and interferences. It doesn’t emits toxic gas during the fire and delays inflammation. Construction 1. Inner Conductor Electrolytic mono annealed copper (HBH) […]

VBAPV / VBAPV-K

TS 2814 PVC Internal Installation Screen Telefon Cables Application These cabels are used indoor installations, central and subscriber distribution cable and signal communications. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (VBAPV) or tinned copper (VBAPV-K) (TS EN 60228, Class 1) 2. Insulation Half […]

VBV / VBV-K

TS 2814 PVC Internal Installation Telephone Cables Application These cabels are used indoor installations, central and subscriber distribution cable and signal communications. Construction 1. Inner Conductor Electrolytic mono annealed copper (VBV) or tinned copper (VBV-K) (TS EN 60228, Class 1) 2. Insulation Half hard PVC (TS EN 50290-2-21 TI51, BS 6746 Type1) TS2814 Core colors […]

KPDF-AP-A/PDF-AP-A

TS 3930 / TS EN 60708 Aerial Type Steel Suspension Wire Filled Telephone Cables Application Such cables are used for external local underground networks and suspension wire air line telephone and signal distribution cables Construction 1. Inner Conductor Electrolytic mono annealed copper, (TS EN 60228, Class 1) 2. Insulation Foam (KP) or Solid (P) Polyethylene, […]

KPD-AP-A/PD-AP-A

TS 3930 / TS EN 60708 Aerial Type Steel Suspension Wire Telephone Cables Application Such cables are used for external local underground networks and suspension wire air line telephone and signal distribution cables Construction 1. Inner Conductor Electrolytic mono annealed copper, (TS EN 60228, Class 1) 2. Insulation Foam (KP) or Solid (P) Polyethylene, (TS3930, […]

KPDF-PAP/PDF-PAP

TS 3930 / TS EN 60708 Underground Type Filled Double Sheahted Telephone Cables Application They are used in the connection and distribution networks of the telephone switchboards, subscribers distribution networks and signal and control circuits. They are installed either in trenches, PVC or concrete conduits or buried directly in the soil. Construction 1. Inner Conductor […]

KPD-PAP/PD-PAP

TS 3930 / TS EN 60708 Underground Type Double Sheathed Telephone Cables Application They are used in the connection and distribution networks of the telephone switchboards, subscribers distribution networks and signal and control circuits. They are installed either in trenches, PVC or concrete conduits or buried directly in the soil. Construction 1. Inner Conductor Electrolytic […]

KPDF-AP/PDF-AP

TS 3930 / TS EN 60708 Underground Type Filled Telephone Cables Application trenches, PVC or concrete conduits or buried directly in the soil. Construction 1. Inner Conductor Electrolytic mono annealed copper, (TS EN 60228, Class 1) 2. Insulation Foam (KP) or Solid (P) Polyethylene, (TS3930, BS 6234 03 C) 2258 TS Cable colors to be […]

KPD-AP/PD-AP

TS 3930 / TS EN 60708 Underground Type Telephone Cables Application They are used in the connection and distribution networks of the telephone switchboards, subscribers distribution networks and signal and control circuits. They are installed either in trenches, PVC or concrete conduits or buried directly in the soil. Construction 1. Inner Conductor Electrolytic mono annealed […]