RG 11/U-4 HF TRI SAT

Cu/PFPE/AL-PES/AL/AL-PES/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]

RG 11/U-4 F TRI SAT

Cu/PFPE/AL-PES/AL/AL-PES/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 11/U-4 HFF SAT

Cu/PFPE/AL-PES/AL/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]

RG 11/U-4 F SAT

Cu/PFPE/AL-PES/AL/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 6/U-6 HFF TRI SHLD

Cu/PFPE/Cu-PES/Cu/Cu-PES/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]

RG 6/U-6 F TRI SHLD

Cu/PFPE/Cu-PES/Cu/Cu-PES/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 6/U-6 F – AP

Cu/PFPE/Cu-PES/Cu/PE+St TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in outdoor aeira line networks in the transmission of both digital and analog image signals CATV, CCTV MATV and CTV distribution, SATV systems wherre low attenuation is required and also security systems. Construction 1. Inner Conductor […]

RG 6/U-6 HFF

Cu/PFPE/Cu-PES/Cu/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]

RG 6/U-6 F

Cu/PFPE/Cu-PES/Cu/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 6/U-4 HFF TRI SHLD

Cu/PFPE/AL-PES/SnCu/AL-PES/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]