RG 59/U-6 F

Cu/PFPE/Cu-PES/Cu/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 59/U-4 HFF

Cu/PFPE/AL-PES/SnCu/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]

RG 59/U-4 F

Cu/PFPE/AL-PES/SnCu/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 59/U-4 SAT HFF

Cu/PFPE/AL-PES/AL/HFFR TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security systems. Construction […]

RG 59/U-4 F SAT

Cu/PFPE/AL-PES/AL/PVC or PE TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in the transmission of both digital and analogue visiual signals in indoor applications distribution of CATV, CCTV, MATV and also CTV signals, in SATV networks where low attenuation is required and also in security […]

RG 11 A/U

SnCu/PE/Cu/PVC Ref. Std. MIL C 17, TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in instruments, devices and alsa antenna systems where low attenuation is required Construction 1. Inner Conductor 7×0,40 mmØ Stranded tinned copper wire 2. Insulation Approx. 7,25 mmØ Solid polyethylene 3. I. […]

RG 216/U

SnCu/PE/Cu/Cu/PVC Ref. Std. MIL C 17, TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in instruments, devices and alsa antenna systems where low attenuation is required Construction 1. Inner Conductor 7×0,40 mmØ Stranded tinned copper wire 2. Insulation Approx. 7,25 mmØ Solid polyethylene 3. I. […]

RG 59 B/U-2

Cu/PE/Cu/PVC Ref. Std. MIL C 17, TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in wireless CB antenna systems and also used as terminal and system connection cable in data communication networks. Construction 1. Inner Conductor 0,60 mmØ Elc. Annealed copper wire 2. Insulation 3,70 […]

RG 59 B/U

StCu/PE/Cu/PVC Ref. Std. MIL C 17, TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 Application It is used as connection cable in wireless CB antenna systems and also used as terminal and system connection cable in data communication networks. Construction 1. Inner Conductor 0,58 mmØ Copper clad steel wire 2. Insulation 3,70 […]

IF-8D-FB

Application It is used as installment and infrastructure cable in GSM systems. Construction 1. Inner Conductor 2,80 mmØ Elc. annealed copper wire 2. Insulation 7,80 mmØ Foam polyethylene 3. I. Screen %100 AL-PES tape shielded 4. II. Screen Tinned copper braiding, approx. %80 coverage 5. Outer Sheath 11,0 mmØ HFFR, RAL 9005 Black General Features […]