| MULTI CHANEL Analog Multichannel Cables |

Application
| Such cables are used in permanent installation for transmission of analog voice signals. |
Construction
| 1. | Inner Conductor | lectrolytic stranded tinned copper tel, 0,22 mm² (EN 60228, Class 2) |
| 2. | Insulation | Solid PE, 1,22 mmØ |
| 3. | Individual Screening | Colored isolateds are twisted with suitable steps which as table 1. Twisted pairs are shilded with AL-PES type and 0,22 mm² (7×0,20) drain wire. AL surface should come in contact with the drain wire for screen continuation. |
| 4. | Inner Sheath | PVC, 3,30 mmØ screened pairs according to tabel 2, according to cable pair numbers are sheathed. On the sheath printed pair number |
| 5. | Available colors sheathed pair from the inside out order of stranded in layers. %100 coverage AL-PES Tape and 0,22 mm² (7×0,20) drain wire with screened. AL surface should come in contact with the drain wire for screen continuation. |
|
| 6. | Outer Sheath | Flexible PVC, Mattete Black |
Technical Properties
| Temperature Range | -30 °C …. +70 °C | |
| Cross Section | 0,22 mm² (7×0,20) | |
| Conductor Resistance (Ом/км) | <86 | |
| Screen DC resistance (Ω/km) | <62 | |
| Capacity | core/core : <65 nF/km, core/screen : <130 nF/km | |
| Empedance 1-6 MHz | 90 Ω | |
| Test Voltage | core/core :500 V, core/screen :1500 V | |
| Insulation resistance | >3,2 |
Documents
AMC 22 |


AMC 22