AMC 22

MULTI CHANEL
Analog Multichannel Cables

AMC 22

Application
Such cables are used in permanent installation for transmission of analog voice signals.
Construction
1. Inner Conductor lectrolytic stranded tinned copper tel, 0,22 mm² (EN 60228, Class 2)
2. Insulation Solid PE, 1,22 mmØ
3. Individual Screening Colored isolateds are twisted with suitable steps which as table 1. Twisted pairs are shilded with AL-PES type
and 0,22 mm² (7×0,20) drain wire. AL surface should come in contact with the drain wire for screen continuation.
4. Inner Sheath PVC, 3,30 mmØ screened pairs according to tabel 2, according to cable pair numbers are sheathed. On the
sheath printed pair number
5. Available colors sheathed pair from the inside out order of stranded in layers. %100 coverage AL-PES Tape
and 0,22 mm² (7×0,20) drain wire with screened. AL surface should come in contact with the drain wire for screen
continuation.
6. Outer Sheath Flexible PVC, Mattete Black
Technical Properties
Temperature Range -30 °C …. +70 °C
Cross Section 0,22 mm² (7×0,20)
Conductor Resistance (Ом/км) <86
Screen DC resistance (Ω/km) <62
Capacity core/core : <65 nF/km, core/screen : <130 nF/km
Empedance 1-6 MHz 90 Ω
Test Voltage core/core :500 V, core/screen :1500 V
Insulation resistance >3,2
Documents
 AMC 22

admin