| Ref. Std. VDE 0815 PVC Internal Installation Communication Cables |

Application
| This type cables, telephone and signal systems are used as fixed indoor installations internal telephone distribution cables. |
Construction
| 1. | Inner Conductor | Electrolytic mono annealed copper (VDE 0295, IEC 60228, Class 1) |
| 2. | Insulation | PVC (EN 50290-2-21, VDE 207; YI1), Core colors according to VDE 0815; |
| 3. | Lay-Up | The cores twisted in star quadruple are bent in groups and fixed with PES tape wound spirally. |
| 4. | Outer Sheath | PVC (EN 50290-2-22;TM51,VDE0207;YM1), It is possible to install open thread under HFFR sheath. RAL 7032 Grey |
General Features
![]() |
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Technical Properties
| Temperature Range | -30 °C …. +70 °C | |
| Operating Voltage | Max. 300 V | |
| Test Voltage | Core/core, 800 V | |
| Min. Bending Radius | 10xD |
Documents
J-YY…Bd |



J-YY…Bd