Ref. Std. VDE 282-15, TS HD 22.15 S1 |
Application
This type of cables can be used in dry, humid and wet places exposed to high temperatures and low temperatures and at +180°C permanently and at up to +220°C shortly. Apart from working at high temperatures, they can also work at low temperatures up to -60°C. These cables are used at iron steel plants, glass and ceramic workshops, foundries, vessel, plane, cement industry, solarium and sauna plants. |
Construction
1. | Inner Conductor | Electrolytic stranded annealed copper wire (IEC 60228, Class 5) |
2. | Insulation | Silicon compound, EI2 Core colours VDE 0293-308 / HD 308 S2 to to be suitable. |
3. | Sheath | Silicon compound, EM9, RAL 3000 Red |
General Features
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 | |
Flame Retardent (For a Bunch of Cable) | IEC 60332-3-24, EN 60332-3-24, VDE 0482-332-3-24 | |
Determination of (Test of determination of flaming droplets) | IEC 60332-1-3, EN 60332-1-3, VDE 0482-332-1-3 | |
Halogen Acid Gas Test | IEC 60754-1, EN 50267-2-1, VDE 0482-267-2-1 | |
Acidic (Corrosive) Gas Test |
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2 | |
Smoke Density Test | IEC 61034-2, EN 61034-2, VDE 0482-1034-2 |
Technical Properties
Temperature Range | Fixed – 60 °C …. +180 °C 4xD / Flexible – 25 °C …. +180 °C 7,5xD | |
Conductor Temperature | +180 °C | |
Short Circuit Temperature | +200 °C |
Documents
SİMH |