Ref. Std. ANSI/TIA/EIA 568-B-ISO/IEC 11801-EN 50173 LAN Cable for Built-in Installation |
Application
Such cables are used for the connections of data communication systems. These cables which are designed for carrying digital and analog voice, data and video signals; ISDN, also support Ethernet 10 Base-T, Fast Ethernet 100 Base-T, Gigabit Ethernet 1000 Base-T, Token Ring 4/16 Mbit/s, TP-PMD/TP-DDI 125 Mbit/s, ATM 155 Mbit/s systems. |
Construction
1. | Inner Conductor | Electrolytic mono annealed copper, 23/24 AWG,(EN 60228, Class 1) |
2. | Insulation | Solid PE (EN 50290-2-23, VDE 0207-2YI1) Core Colors will be appropriate according to IEC 189. (Table 1) |
3. | Lay-Up | Cores twisted in pairs, and all the pairs are twisted with seperator. |
4. | Screen | It is screened together with both %100 covered, helically wrapped AL-PES tepe and also twisted, tinned copper draining wire. AL surface should come in contact with the drain wire for the continuation of the screen |
5. | Outer Sheath | PVC (EN 50290-2-22) RAL 7032, Grey, HFFR (EN 50290-2-27, VDE 0207), RAL 7032, Grey |
General Features
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 | |
Halogen Acid Gas Test | IEC 60754-1, EN 50267-2-1, VDE 0482-267-2-1 | |
Acidic (Corrosive) Gas Test |
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2 | |
Smoke Density Test | IEC 61034-2, EN 61034-2, VDE 0482-1034-2 |
Technical Properties
Operating Voltage | -20 °C …. +60 °C | |
Operating Voltage | 72 V DC max | |
Test Voltage | 1500 V | |
Min. Bending Radius | 8xD |
Documents
F/UTP Cat6 PVC/LSOH |