Ref. Std. VDE 0815 PVC Internal Installation Communication Cables Application This type cables, telephone and signal systems are used as fixed indoor installations internal telephone distribution cables. Construction 1. Inner Conductor Electrolytic mono annealed copper (VDE 0295, IEC 60228, Class 1) 2. Insulation PVC (EN 50290-2-21, VDE 207; YI1), Core colors according to VDE 0815; […]
Ref. Std. VDE 0815 HFFR Internal Installation Communication Cables Application This type of cable are use fixed indoor installations and signal communicaiton. The screen protects the cable core against electrical noises and interferences. They don’t emit toxic gas if they are burned, prevent flame propagation and feature low smoke intensity. Construction 1. Inner Conductor Electrolytic […]
Ref. Std. VDE 0815 PVC Internal Installation Comunication Cables Application This type of cable are use fixed indoor installations and signal communicaiton. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (VDE 0295, IEC 60228, Class 1) 2. Insulation PVC (EN 50290-2-21, VDE 207; YI1), […]
Ref. Std. VDE 0815 PVC Internal Installation Fire Alarm Cables Application This type of cable are use fixed indoor installations and signal communicaiton. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (IEC 60228, VDE 0295 Class 1) 2. Insulation PVC (VDE 0207; YI3), Core […]
ef. Std. VDE 0815 HFFR Internal Installation Fire Alarm Cables Application This type of cable are use fixed indoor installations and signal communicaiton. The screen protects the cable core against electrical noises and interfer- ences. They don’t emit toxic gas if they are burned, prevent flame propagation and feature low smoke intensity. Construction 1. Inner […]
Ref. Std. VDE 0815 PVC Internal Installation Telephone Cables Application This type of cable are use fixed indoor installations and signal communicaiton. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (IEC 60228, VDE 0295, Class 1) 2. Insulation PVC (EN 50290-2-21, VDE 207; YI1), […]
Ref. Std. VDE 0815 PVC Internal Installation Telephone Cables Application This type of cable are use fixed indoor installations and signal communicaiton. The screen protects the cable core against electrical noises and interferences. Such cables are used fixed indoor installations. Construction 1. Inner Conductor Electrolytic mono annealed copper (VDE 0295, IEC 60228, Class 1) 2. […]
TS 2814/TS 3930 PE Isolated Quad Twisted PVC Sheathed Screened Internal Installation Telephone Cables Application These cabels are used indoor installations, central and subscriber distribution cable and signal communications. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (PDAPV), Kalay kaplı tavlı bakır (PDAPV-K), (TS […]
TS 2814/TS 3930 PE Isolated Quad Twisted PVC Sheathed Internal Installation Telephone Cables Application These cabels are used indoor installations, central and subscriber distribution cable and signal communications. Construction 1. Inner Conductor Electrolytic mono annealed copper (PDV), tin coated annealed copper (PDV-K), (TS EN 60228, Class 1) 2. Insulation PE Isolated (TS EN 50290-2-, BS […]
Ref. Std. TS 2814 HFFR, Internal Installation Screened Telephone Cables Application These cabels are used indoor installations, central and subscriber distribution cable and signal communications. The screen protects the cable core against electrical noises and interferences. The screen protects the cable core against electrical noises and interferences. It doesn’t emits toxic gas during the fire […]