Ref. Std. VDE 0816 Filled External Installation Telephone Cables Application This cables are used to be external local networks as telephone and signal transmission cables. The must be installed by embedding to underground. Construction 1. Inner Conductor Electrolytic mono annealed copper (IEC 60228, VDE 0295, Class 1) 2. Insulation PE (EN 50290-2-23, VDE 0207 2YI2) […]
Ref. Std. VDE 0816 Unfilled External Installation Telephone Cables Application This cables are used to be external local networks as telephone and signal transmission cables. The must be installed by embedding to underground. Construction 1. Inner Conductor Electrolytic mono annealed copper (IEC 60228, VDE 0295, Class 1) 2. Insulation PE (EN 50290-2-23, VDE 0207 2YI1) […]
Application PCM cables are used as distribution cable between PCM devices in digital transmission systems for signal transmission between 300 – 3600 VF (voice frequency) and digital signal transport at 2,048 Mbps. Construction 1. Inner Conductor Electrolytic mono tinned copper wire , 0.4 or 0.5 mm çapında (EN 60228, Class 1) 2. Insulation Solid PE […]
Application PCM cables are used as distribution cable between PCM devices in digital transmission systems for signal transmission between 300 – 3600 VF (voice frequency) and digital signal transport at 2,048 Mbps. Construction 1. Inner Conductor Electrolytic mono tinned copper wire , 0.4 or 0.5 mm diameter (EN 60228, Class 1) 2. Insulation Solid PE […]
Application PCM cables are used as distribution cable between PCM devices in digital transmission systems for signal transmission between 300 – 3600 VF (voice frequency) and digital signal transport at 2,048 Mbps. Construction 1. Inner Conductor Electrolytic mono tinned copper wire , 0.4 or 0.5 mm diameter (EN 60228, Class 1) 2. Insulation Solid PE […]
Application PCM cables are used as distribution cable between PCM devices in digital transmission systems for signal transmission between 300 – 3600 VF (voice frequency) and digital signal transport at 2,048 Mbps. Construction 1. Inner Conductor Electrolytic mono tinned copper wire , 0.4 or 0.5 mm çapında (EN 60228, Class 1) 2. Lay-Up Pair twisted […]
Central Cables Application These cables are, used as system connection cable central installations. Construction 1. Inner Conductor Electrolytic mono tinned copper wire , 0.5 mm (24AWG) mm (TS EN 60228, Class 1) 2. Insulation Half hard will be isolated PVC (BS 6746 TYPE1). According to Table 1, core colors to be appropriate. 3. Lay-Up Two […]
Central Cables Application These cables are, used as system connection cable central installations. Construction 1. Inner Conductor Electrolytic mono tinned copper wire , 0.4 mm (26AWG) mm (TS EN 60228, Class 1) 2. Insulation Half hard will be isolated PVC (BS 6746 TYPE1). According to Table 1, core colors to be appropriate. 3. Lay-Up Two […]
B.P.V.C.T. Application These cables are used, externally installed telephone lines, tranmission lines, sound equipment, intercom systems, repetitor and field warehouses. Construction 1. Inner Conductor Electrolytic mono tinned or annealed copper (EN 60228, Class 1) 2. Insulation PVC (EN 50290-2-21; TI52), insulated core colors will be suitable, according to Table1. 3. Lay-Up The conductors insulated with […]
Ref. Std. VDE 0815 HFFR Internal Installation Communication Cables Application This type cables, telephone and signal systems are used as fixed indoor installations internal telephone distribution cables. They don’t emit toxic gas if they are burned, prevent flame propagation and feature low smoke intensity. Construction 1. Inner Conductor Electrolytic mono annealed copper (VDE 0295, IEC […]