Ref. Std. VDE 0815 HFFR Building Automation Cables Application These cables are used for signal transmission in internal building installations. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (EN 60228, Class 1) 2. Insulation HFFR (EN 50290-2-26, VDE 0207 HI2) Core colors according to […]
Ref. Std. VDE 0815 PVC Building Automation Cables Application These cables are used for signal transmission in internal building installations. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (EN 60228, Class 1) 2. Insulation PVC (EN 50290-2-21, VDE 207; YI1, Core colors according to […]
Ref. Std. CC-Link Specification 1.10, CM +75°C/+167°F or PLTC Application These cables are used for signal transmission in internal building installations. The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic twisted annealed copper (EN 60228, Class 2) AWG20/7 2. Insulation Foam PE, core colors: White, Blue, Yellow 3. […]
LI-2Y(St)CYSWAY-fl 1x2x1,0 mmØ Ref. Std. PROFI-BUS ISA/SP-50, EN 50170 Application Such cablesare used for high-speed data transmission in indoor installation applications. Construction 1. Inner Conductor Electrolytic mono annealed copper (EN 60228, Class 1) AWG 18 2. Insulation PE, Core colors: Red, Green 3. Lay-Up Twisted in suitable pitch together with 2 cords.(Shape 1) 4. I. […]
LI-2Y(St)CY-fl 1x2x1,0 mmØ Ref. Std. PROFI-BUS ISA/SP-50, EN 50170 Application Such cablesare used for high-speed data transmission in indoor installation applications. Construction 1. Inner Conductor Electrolytic mono annealed copper (EN 60228, Class 1) AWG 18 2. Insulation PE, Core colors: Red, Green 3. Lay-Up Twisted in suitable pitch togetherwith 2 cords.(Shape 1) 4. I. Screen […]
LI-O2YS(St)CY-fl 1x2x22AWG Ref. Std. PROFI-BUS ISA/SP-50, DIN 19245T3, EN 50170 Application Such cables are used in high-speed data transmission, like indoor installation of up to 12 Mbps (up to 100 m long). The screen protects the cable core against electrical noises and interferences. Construction 1. Inner Conductor Electrolytic mono annealed copper (EN 60228, Class 1) […]
KD-4654 Ref. Std. NEC CMP-PCC FT 4 Application This short of cables are usedas symmertic data cables both in computer terminals and also in printers. Construction 1. Inner Conductor Electrolytic twisted tinned copper and electrolytic twisted annealed copper (EN 60228, Class 2) 2. Insulation Solid PE (EN 50290-2-23), core colors: Transparent 3. Lay-Up Cores are […]
KD-4653 Ref. Std. NEC CMP-PCC FT 4 Application This short of cables are usedas symmertic data cables both in computer terminals and also in printers. Construction 1. Inner Conductor Electrolytic twisted tinned copper wire (EN 60228, Class 2) 2. Insulation Solid PE (EN 50290-2-23), Core colors: White, Blue 3. Lay-Up Twisted in suitable pitch together […]
Ref. Std. EIA RS 485 KPE Insulated, Individual And General Screen Data Cables Application This sort of cables are used as signal and transmission cables in the electronical control systems and also in the transmission of voice frequency. Their halogen-free counterparts are distinguished with flame retarding and low smoke features. Construction 1. Inner Conductor Electrolytic […]
Ref. Std. EIA RS 485 KPE Insulated, Individual And General Screen Data Cables Application This sort of cables are used as signal and transmission cables in the electronical control systems and also in the transmission of voice frequency. Their halogen-free counterparts are distinguished with flame retarding and low smoke features. Construction 1. Inner Conductor Electrolytic […]