Ref. Std. VDE 0816 Filled External Installation Telephone Cables |
Application
This cables are used to be external local networks as telephone and signal transmission cables. The must be installed by embedding to underground. |
Construction
1. | Inner Conductor | Electrolytic mono annealed copper (IEC 60228, VDE 0295, Class 1) |
2. | Insulation | PE (EN 50290-2-23, VDE 0207 2YI2) Core colours are isolated according to VDE 0816 and following that a ring code is pressed |
3. | Lay-Up | Star shaped sub-groups which are twisted in the form of quarters or groups which are composed of five (5) quarterly de signed cores are twisted. |
4. | Filled | Akind of waterprof petroleum jelly which has a special chemical structure is injected into the inner-side of the cable core. Then, two paper-based tapes which are in the shape of coils are helically wrapped around this petroleum jelly. |
5. | Screen | Screening is made by attaching PE-AL-PES tape whose two sidesare covered wiyh PE tape in the shape of a tube troughout the entire cable. |
6. | Outer Sheath | PE (VDE0207 2YM2), RAL Black |
Technical Properties
Temperature Range | -20 °C …. +50 °C | |
Operating Voltage | Max. 225 V | |
Test Voltage | Core/core 500 V, core/screen 2000 V 10xD K1: %98 < 400 pF/300 m K9 – K12: %98 < 100 pF/300 m |
|
Min. Bending Radius | 10xD |
Documents
A-2YF(L)2Y St III Bd |