Application
PCM cables are used as distribution cable between PCM devices in digital transmission systems for signal transmission between 300 – 3600 VF (voice frequency) and digital signal transport at 2,048 Mbps. |
Construction
1. | Inner Conductor | Electrolytic mono tinned copper wire , 0.4 or 0.5 mm çapında (EN 60228, Class 1) |
2. | Lay-Up | Pair twisted cores, up to 20 pair twisted in layers and fixed with PES tape |
3. | Screen | AL-PES tape with together (0,40 and/or 0,50 mmØ) mono tinned copper drain wire with screened. For screen to continue, AL surface contact with drain wire. |
4. | Outer Sheath | HFFR (EN 50290-2-27), RAL 7032, Grey or RAL 7001 Coated with grey. |
General Features
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 | |
Halogen Acid Gas Test | IEC 60754-1, EN 50267-2-1, VDE 0482-267-2-1 | |
Acidic (Corrosive) Gas Test |
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2 | |
Smoke Density Test | IEC 61034-2, EN 61034-2, VDE 0482-1034-2 |
Technical Properties
Temperature Range | -30 °C …. +70 °C | |
Operating Voltage | 350 V | |
Test Voltage | 1500 V | |
Min. Bending Radius | 15xD |
Documents
J-2Y(St)H 2Mbit PCM Kablo |