TS 2814/TS 3930 PE Isolated Quad Twisted PVC Sheathed Internal Installation Telephone Cables |
Application
These cabels are used indoor installations, central and subscriber distribution cable and signal communications. |
Construction
1. | Inner Conductor | Electrolytic mono annealed copper (PDV), tin coated annealed copper (PDV-K), (TS EN 60228, Class 1) |
2. | Insulation | PE Isolated (TS EN 50290-2-, BS 6234-03C) TS2258 Core colors to be appropriate.(Table 2) |
3. | Lay-Up | The cores twisted in star quadruple are bent, up to 10 pairs quadruple, after 10 pairs to 5 quad (1) group, 5 or 10 group bend (1) packet to be bent. Over ten pairs are fixed with PES tape. The groups and packages are tagged with color threads.(Table 3) |
4. | Outer Sheath | PVC (TS EN 50290-2-22 TM51, BS 6746 Tip3), RAL 7032 Grey |
General Features
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Technical Properties
Temperature Range | -30 °C …. +70 °C | |
Operating Voltage | 250 V | |
Test Voltage | 1500 V | |
Min. Bending Radius | 7,5xD |
Documents
PDV / PDV-K |