VBAPV / VBAPV-K

TS 2814
PVC Internal Installation Screen Telefon Cables

VBAPV / VBAPV-K

Application
These cabels are used indoor installations, central and subscriber distribution cable and signal communications. The screen protects the cable core against electrical noises and interferences.
Construction
1. Inner Conductor Electrolytic mono annealed copper (VBAPV) or tinned copper (VBAPV-K) (TS EN 60228, Class 1)
2. Insulation Half hard PVC (TS EN 50290-2-21,TI51, BS 6746 Tip1) TS2814 Core colors to be appropriate.(Table 2)
3. Lay-Up wisted pairs cores are, up to 20 pairs in layers, between 30-100 pairs, 10 pairs in groups, after 100 pairs stranded with 50 pairs and fixed with PES tape. The groups and packages are tagged with color threads.(Table 3)
4. Screen AL-PES tape with together (0,50 mmØ) mono tinned copper drain wire with screened. For screen to continue, AL surface contact with drain wire.
5. Outer Sheath PVC (TS EN 50290-2-22 TM51, BS 6746 Tip3), RAL 7032, Grey
General Features
Flame Retardent
(For Single Cable)
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Technical Properties
Temperature Range -30 °C …. +70 °C
Operating Voltage 250 V
Test Voltage 1500 V
Min. Bending Radius 7,5xD
Documents
 VBAPV / VBAPV-K

admin