VBV / VBV-K

TS 2814
PVC Internal Installation Telephone Cables

VBV / VBV-K

Application
These cabels are used indoor installations, central and subscriber distribution cable and signal communications.
Construction
1. Inner Conductor Electrolytic mono annealed copper (VBV) or tinned copper (VBV-K) (TS EN 60228, Class 1)
2. Insulation Half hard PVC (TS EN 50290-2-21 TI51, BS 6746 Type1) TS2814 Core colors to be appropriate.(Table 2)
3. Lay-Up Bending of the cores twisted in pairs is conducted as layers up to 20 pairs, in group of 10-pairs between 30 – 100 pairs, and in 50-pairs above
100 pairs. The cables consisted above 10 pairs are fixed with PES tape. The groups and packages are tagged with color threads (Table 3).
4. Drain Single core is used on white PVC, as coded with red color.
5. Outer Sheath PVC (TS EN 50290-2-22 TM51, BS 6746 Tip3), RAL 7032, Grey
General Features
Flame Retardent
(For Single Cable)
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Technical Properties
Temperature Range -30 °C …. +70 °C
Operating Voltage 250 V
Test Voltage 1500 V
Min. Bending Radius 7,5xD
Documents
 VBV / VBV-K