| Ref. Std. VDE 0812 Intercom Cable |

Application
| Such cables are used in-building installation for internal communication and voice systems as well as in diaphone systems. |
Construction
| 1. | Inner Conductor | 14×0,15 mmØ Electrolytic stranded annealed copper (IEC 60228 Class 5) |
| 2. | Isolated | PVC, (EN 50290-2-21) (White,Green, Red, Yellow, Pink, Grey, Blue, Black) |
| 3. | Lay-Up | Insulated cores are stranded with layers, fixed with Pes-Tape |
| 4. | Outer Sheath | 5,70 mmØ PVC (EN 50290-2-22), RAL 9003 White |
Technical Properties
| Temperature Range | -30 °C …. +70 °C | |
| Operating Voltage | Max. 250 V | |
| Test Voltage | 1200 V | |
| Min. Bending Radius | 10xD (D:Cable Diameter) |
Documents
DT-8 |


DT-8