Application
| These cables are used in closed circuit TV viewing, visual telephone systems and video sytems |
Construction
| 1. | Coax. Inner conductor | 0,81 mmØ Electrolytic annealed copper |
| 2. | Coax. Insulation | Approx. 3,66 mmØ Physical foamed polyethylene |
| 3. | Coax. I. and II. Screen | %100 AL-PES tape shielded and Tinned copper wire, |
| 4. | Data Conductor | 7×0,20 mmØ (0,22 mm²) Stranded annealed copper or tinned copper wire (IEC 60228) |
| 5. | Data Isolated | PVC / HFFR insulated (TS EN 50290-2) Green, Yellow colour |
| 6. | Power Insulation | 16×0,19 mmØ (0,50 mm²) Stranded annealed copper or tinned copper wire (IEC 60228) |
| 7. | Power Isolated | PVC / HFFR insulated (TS EN 50290-2) Red, Blue colour |
| 8. | Overall Screen | Screening is made by combining coaxial cable and the control cores to each other by the appropriate pitch and then by screening this combination with Al-PES. |
| 9. | Outer Sheath | 7,50 mmØ PVC / HFFR / PE (EN 50290-2), PVC – RAL 7001 Grey / HFFR – RAL 7001 Grey / PE – RAL 9005 Black |
General Features
![]() |
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
![]() |
Halogen Acid Gas Test | IEC 60754-1, EN 50267-2-1,VDE 0482-267-2-1 (HFFR için) |
![]() |
Acidic (Corrosive) Gas Test |
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2 (HFFR için) |
![]() |
Smoke Density Test | IEC 61034-2, EN 61034-2, VDE 0482-1034-2 (HFFR için) |
Technical Properties
| Temperature Range | -30 °C …. +70 °C | |
| Operating Voltage | Max. 300 V | |
| Test Voltage | 1200 V | |
| Min. Bending Radius | 15xD (D:Cable Diameter) |
Documents
CCTV RG 59/U-4+2×0,22+2×0,50 mm² |






CCTV RG 59/U-4+2×0,22+2×0,50 mm²