RG 216/U

SnCu/PE/Cu/Cu/PVC
Ref. Std. MIL C 17, TS EN 50117, TS 2637
IEC 60096-1, TS 5757 IEC 60096-3

RG 216/U

Application
It is used as connection cable in instruments, devices and alsa antenna systems where low attenuation is required
Construction
1. Inner Conductor 7×0,40 mmØ Stranded tinned copper wire
2. Insulation Approx. 7,25 mmØ Solid polyethylene
3. I. Screen Elc. annealed copper braiding, approx. %95
• Elk.
4. II. Screen Elc. annealed copper braiding, approx. %92
5. Outer Sheath 10,8 mmØ PVC (EN 50290-2-22), RAL 9005 Black
General Features
Flame Retardent
(For Single Cable)
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Technical Properties
Temperature Range -30 °C …. +70 °C
Operating Voltage Max. 5 kV
Test Voltage 8 kV
Min. Bending Radius 5xD (D:Cable Diameter)
Documents
 RG 216/U

admin