| Ref. Std. MIL C 17, TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 |

Application
| It is used as connection cable in wireless CB antenna systems and also used as terminal and system connection cable in data communication networks. |
Construction
| 1. | Inner Conductor | 0,91 mmØ Stranded silver coated copper wire |
| 2. | Insulation | Approx. 2,95 mmØ Solid polyethylene |
| 3. | I. Screen | Silver coated copper braiding, approx. %95 |
| 4. | II. Screen | Silver coated copper braiding, approx. %93 |
| 5. | Outer Sheath | 5,40 mmØ PVC (EN 50290-2-22), RAL 9005 Black or RAL 9003 White |
General Features
![]() |
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Technical Properties
| Temperature Range | -40 °C …. +70 °C | |
| Operating Voltage | Max. 2500 V | |
| Test Voltage | 5000 V | |
| Min. Bending Radius | 10xD (D:Cable Diameter) |
Documents
RG 223/U |



RG 223/U