Ref. Std. MIL C 17, TS EN 50117, TS 2637 IEC 60096-1, TS 5757 IEC 60096-3 |
Application
It is used as connection cable in wireless CB antenna systems and also used as terminal and system connection cable in data communication networks. |
Construction
1. | Inner Conductor | 7×0,75 mmØ Stranded silver-coated |
2. | Insulation | Approx. 7,25 mmØ Solid polyethylene |
3. | I. Screen | Silver coated copper braiding, approx. %95 |
4. | II. Screen | Silver coated copper braiding, approx. %93 |
5. | Outer Sheath | 10,8 mmØ PVC (EN 50290-2-22), RAL 9005 Black |
General Features
Flame Retardent (For Single Cable) |
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2 |
Technical Properties
Temperature Range | -40 °C …. +70 °C | |
Operating Voltage | Max. 5 kV | |
Test Voltage | 10 kV | |
Min. Bending Radius | 10xD (D:Cable Diameter) |
Documents
RG 214/U |