KPD-AP/PD-AP

TS 3930 / TS EN 60708
Underground Type Telephone Cables

KPD-AP/PD-AP

Application
They are used in the connection and distribution networks of the telephone switchboards, subscribers distribution networks and signal and control circuits. They are installed either in trenches, PVC or concrete conduits or buried directly in the soil.
Construction
1. Inner Conductor Electrolytic mono annealed copper, (TS EN 60228, Class 1)
2. Insulation Foam (KP) or Solid (P) Polyethylene, (TS3930, BS 6234 03 C) 2258 TS Cable colors to be appropriate.(Table 1)
3. Lay-Up Twisting is performed for star quadruple (D) twisted cores as star-quadruples up to 10 pairs, or 5 quadruples (1) group after 10 pairs or 10 group twisting (1) package and fixed with moisture free PES tape with dielectric feature. The groups and packages are tagged with color threads.
4. Screen Both sides PE film coated Aleminium foil
5. Outer Sheath Low (LD) or middle (MD) density Polythene (ASTM D 1248); RAL 9005 Black
HFFR (TS EN 50290-2-27) RAL 7001 Grey
General Features
Flame Retardent
(For Single Cable)
IEC 60332-1-2, EN 60332-1-2, VDE 0482-332-1-2
Halogen Acid Gas Test IEC 60754-1, EN 50267-2-1, VDE 0482-267-2-1
Acidic (Corrosive)
Gas Test
IEC 60754-2, EN 50267-2-2, VDE 0482-267-2-2
Smoke Density Test IEC 61034-2, EN 61034-2, VDE 0482-1034-2
*These tests are only applied to HFFR cables.
**Yangın esnasında yoğun duman and toksik gaz çıkarmayan, asit emisyonu olmayan, yangın esnasında can and mal güandnliğini en üst seviyede tutan LSOH özellikli HFFR malzeme ile kılıflanarak KPD-AH Cable olarak üretilebilir.
Technical Properties
0,40 / 0,50 / 0,60 / 0,90
Temperature Range -30 °C …. +70 °C
Operating Voltage Max. 300 V
Test Voltage 1200 V DC / 2000 V DC / 3000 V DC
Min. Bending Radius 15xD
Documents
 KPD-AP/PD-AP